DTSD309 three-phase four-wire multi-function watt-hour meter (full-featured)
Scope of application

1, the measurement function: measuring positive and negative active, capacitive reactive power and round quadrant reactive energy;

2, time-measurement: with four rates, 12 time zones, divided into 10 days a day, a total of 4 sets of day time to choose from;

3, the monthly statistics of electricity: a total power and time sharing power and the total function of the previous day and last month's total electricity consumption measurement function;

4, the maximum demand: record the maximum demand and its emergence time, demand cycle default is 15 minutes, slip time default is 1 minute;

5, clock, calendar function (summer time 10 years automatic conversion)

6, power failure display (optional)

7, time recording function: record the occurrence time of a variety of events and the current state, such as phase failure, power failure, programming, reset, battery usage,

8, communication function: can use RS485 communication interface or infrared port, and handheld computers, computers or infrared remote control to communicate.

Main technical parameters and specifications

Model and name

Accuracy (level)

Reference voltage (V)

Calibration current (A)

Wiring

Packing size (mm)

Quantity (only)

DTSD309

Three-phase four-wire multi-function

Meter

(Simple multi-function)

1.0

2.0

3×57.7/100

3×220/380

1.5(6)

Mutual inductance



5(20),10(40)

15(60),20(80),30(100)

Direct type

DTSD309

Three-phase four-wire multi-function

Meter

(Full Function)

1.0

2.0

3×57.7/100

3×220/380

1.5(6)

Mutual inductance

5(20),10(40)

15(60),20(80),30(100)

Direct type

DTZ309

Three-phase four-wire charge control

Smart energy meter

1.0

2.0

3×57.7/100

3×220/380

1.5(6)

Mutual inductance



5(20),10(40)

15(60),20(80),30(100)

Direct type

standard

Meet the JB / T7656-1995, DL / T614-1997 requirements

Pulse constant

By nameplate standard

Reference frequency

50HZ±5%

Clock error

≤0.5S/d

Mean time between failures (MTBF)

≥5×10?h

Power consumption

<2W,10VA

Normal operating voltage

(0.9~1.1)Vh

Limit operating voltage

(0.7~1.2)Vh

Ambient temperature

(-25~55)℃

Limit temperature

(-25~70)℃

Relative humidity

≤75% (annual average temperature)

Design life

15 years

Spare battery life

10 years

Pulse output parameter

Pulse width (80 ± 20) ms Voltage amplitude ≤ DC24V Passive